Johnson Service Bulletin SB-975 - Engines Jumping Out of Gear
Issued August 23, 1963, this bulletin explains how clamp 309041 could damage electric shift wiring on 75 HP engines, causing momentary loss of gear engagement or a blown 20-amp ignition key switch fuse.
August 23, 1963
Subject: a - ENGINES JUMPING OUT OF GEAR
b - 20 AMP IGNITION KEY SWITCH FUSE BLOWING
On Engines: MODELS V4A (L)-14 THRU 15E
Midway through the 1963 model year, #309041 clamp was added to the crankcase oil drain
hose on all 75 h.p. engines. (Ref. Service Bulletin #SB-937 dated 1/14/63).
We have recently received reports that the lip of #309041 clamp is fraying the wire
loom which houses the electric shift leads (See Arrow, Figure 1). These reports
further advise that #309041 clamp has, in some cases, worn through both wire loom covering
and shift lead insulation. The result is a short (grounding of shift lead wire to
#309041 clamp) which interrupts the electric shift coupling - allowing the engine to
jump out of gear momentarily.
FIGURE 1
FIGURE 2
In view of this problem we suggest checking for #309041 clamp on each electric shift
75 H.P. engine that comes into the shop - especially those engines which the owners
claim are jumping out of gear. If the engine includes this clamp - merely remove it
and turn it around so that its hook faces toward the powerhead (See Arrow, Figure 2).
So doing turns the hook away from the wire loom and eliminates the possibility of
wire loom fraying from contact with the clamp's lip. After repositioning the clamp,
carefully tape any frayed area on the shift lead with a good brand of electrical tape.
(over)
Page 2
SB-# 975
1963 electric shift 75 H.P. engines also have a 20 AMP fuse between the ammeter and
ignition key switch. It's possible that this fuse may blow in event the electric shift
lead shorts against #309041 clamp. Replacing this fuse will again render the ignition
and shift circuits operative, but will not protect against repeat fuse failure.
Therefore, blown ignition key fuses also indicate the possibility of a short between
#309041 clamp and shift lead wire.
Summary:
The foregoing is a known source of trouble and should always be considered when
diagnosing malfunction in the electric shift circuit. However, shift circuit malfunction
can similarly occur as a result of wiring shorts in other areas, principally on engines
that have had the electrical wiring "rerouted" by either an inexperienced mechanic or
by the owner himself.
Check especially for electrical wiring rubbing against areas where sharp diecast flashing
may exist. Also, check for wear between the wire loom and starter mounting bracket on
engines equipped with a Delco Remy Starter Motor. These are just a few examples of
where shorts may exist in the electric shift circuit if the wire loom has been
"rerouted".
Sincerely,
Robert Compton
Administrative Assistant
RC/bk
NOTE: Post on your V-75 Index.
Related factory reference
See Johnson SB-937 for the earlier introduction of clamp 309041 on the crankcase oil drain hose. SB-975 describes how to reposition the clamp to avoid damaging the electric shift wiring.