Evinrude Service Bulletin #1077: Stator Service on 85 thru 135 H.P. Models with Magneto C.D. Ignition

Issued March, 1975. Factory electrical guidance for Evinrude service technicians and dealers.

Evinrude Service Bulletin factory header
ELECTRICAL #1077
March, 1975
STATOR SERVICE ON 85 THRU 135 H.P. MODELS WITH MAGNETO C.D. IGNITION

If you are replacing the stator and have evidence of overheating of the charge coils (protective finish melted) make sure you check out the complete alternator circuit before putting the engine back into operation. In almost all charge coil failures of this type, the cause is an open circuit in the charging system. When the alternator circuit opens, excessive current passes through the stator resulting in heat building up in the charge coils to the point of failure.

Refer to the appropriate service manual for detailed alternator circuit test procedures. If a failed rectifier is found, the cause is most likely a loose or corroded electrical connection or a battery which has been improperly connected producing reverse polarity. Make sure the cause of the failure is found and corrected before returning the engine to service.

EVINRUDE MOTORS
Service Department