Evinrude Service Bulletin #1149 - V-6 Instrument Cable

This revised May 1977 bulletin explains how some 175 and 200 HP V-6 motors were shipped with V-4 instrument cable assemblies. It describes the battery-cable size check and the return procedure.

Evinrude Service Bulletin
Controls #1149 (Rev.)

May, 1977

SUBJECT: V-6 INSTRUMENT CABLE

It has been reported that a few 1977 175 and 200 H.P. V-6 motors were shipped with the P/N 281043 V-4 instrument cable assembly instead of the P/N 281044 V-6 cable. The cartons are stamped correctly P/N 281044 however, they have the 281043 V-4 cable packed inside. Open the carton and measure the battery cables as shown in Figure 1.

If a 1977 V-6 hard starting problem is reported, inspect the battery cables first. The V-4 instrument cable assembly attached to the remote control unit, has lighter gauge battery cables and could cause slower cranking speeds and possible hard starting under some conditions.

The V-6 battery cables are approximately 3/8" O.D. #4 GA. vs 5/16" #6 GA. for the V-4 cables. See Figure 1.

Factory Figure 1: V-6 and V-4 instrument cable comparison

NOTE: Prolonged and excessive cranking, due to small battery cables or other problems, can cause premature wear and damage to starter motor.

If any V-4 cables are found in V-6 cartons, return the complete remote control assembly with all hardware to our Service Department. We will return a complete P/N 281044 V-6 remote control assembly on receipt of the incorrect assembly.

EVINRUDE MOTORS