SUBJECT: GEARCASE LUBRICANT LEVEL - ALL MODELS
Our Warranty Department has reported that several gearcases have been returned with major component failures due to low lubricant level.
□ NOTE
INSUFFICIENT GEARCASE LUBRICANTS WILL CAUSE SERIOUS DAMAGE TO LOWER UNIT COMPONENTS.
We highly recommend that dealers check the gearcase lubricant level on all new motors, and “top off,” if necessary, before delivering to the customer. This should be done slowly, as many gearcases require air to escape to allow gearcase lubricant to reach proper level.
All Owner’s/Operator’s Manuals state that the gearcase lubricant should be changed after the first 20 hours of operation and checked after 50 hours of operation. Add lubricant, if necessary. Drain and refill every 100 hours of operation or once each season, whichever occurs first.