SUBJECT: CLEANING DISTRIBUTOR CAPS AND ROTORS
We have found that a very high percentage of so-called defective distributor caps and rotors returned from the field, which have been replaced under warranty, are in fact not defective at all.
By proper cleaning of these returned caps and rotors, most of them were restored to serviceable condition. Therefore, prior to replacement of these components, they should be properly cleaned and tested for leakage by probing them in accordance with service manual instructions.
A good greaseless cleaning solvent should be used such as, Tempo Instant Spray Alternator-Generator Cleaner #20-013, which is readily available from your Parts Distributor. Denatured alcohol or trichlorethylene may also be used. Wipe the cap and rotor with a clean cloth to make sure all dirt or residue is removed.
When reinstalling the high tension leads in the distributor cap, fill the towers 1/3 full of OMC Type "D" lubricant.
JRP:rm
NOTE: Post on your 55 through 115 H.P. Indexes under the heading "Ignition."