Issued October 1971, this Johnson Service Bulletin explains the replacement hydroelectric gearcase oil pump, a revised reverse gear for 55-60 H.P. models, and the clearance between the propeller shaft and reverse gear. Both factory illustrations and the original parts comparison are reproduced below.
SB-#1274
October, 1971
SUBJECT: Service Information on Hydroelectric Gearcases
ON MODELS: All Engines with Hydroelectric Gearcases
For the 1971 hydroelectric shifting models we came out with a new
oil pump part number 385056. This new pump supersedes part number
383537 which was used in the earlier hydroelectric gearcases.
When replacing a oil pump part number 383537 with the newer oil
pump part number 385056 you cannot reinstall the forward snap
ring. The forward gear thrust bearing will keep the pump in place,
even though it is a smaller diameter bearing than the 1971 forward
thrust bearing.
NEW STYLE REVERSE GEAR 55-60 HP MODELS
A change has been made to the reverse gear that has caused some
concern among dealers as to interchangeability. The following indi-
cates the reverse gear installed as original equipment when produced:
OLD STYLE REVERSE GEAR W/BUSHING | ORIGINAL EQUIP. ON MODEL | NEW STYLE REVERSE GEAR | ORIGINAL EQUIP. ON MODEL |
|---|
| 382309 | 1968-1969 55HP 1970 60 HP | 316522 | 1971 60 HP |
The original old style gears had a bushing. These gears are no longer
available and have been superseded by the new style reverse gear.
(See Figure 1).

(over)
PAGE 2 SERVICE BULLETIN SB-#1274
JOHNSON MOTORS, DIVISION OF OUTBOARD MARINE CORPORATION, WAUKEGAN, ILLINOIS 60085
The reverse gear pilots on the outside surface which is held in
place by the Bearing Housing and Seal Assembly. (See Figure 2 "A").
The inside diameter simply facilitates the passage of the propeller
shaft through the gear without directly contacting the shaft. Note
the considerable clearance between propeller shaft outside diameter
and the reverse gear inside diameter. (See Figure 2 "B").

JOHNSON MOTORS
Doug Cankar
Technical Data Coordinator
DC/sn
NOTE: Post on your 50 through 125 H.P. under the heading "Lower Unit".