Johnson Service Bulletin SB-1312 Rev. 1 (March 1973) - Jumper Cables and Battery Charging Units
Johnson's revised 1973 bulletin explains safe jumper-cable connection and removal procedures, battery charging precautions, and risks to electrical components on electric-start outboards and stern drives.

We have received several inquiries regarding the advisability of using jumper cables or small "home charging units" on outboard engines and stern drives.
It is safe to connect jumper cables between boats to start a disabled engine, but only if it is done in a proper manner. We recommend that the positive connection be securely made at the positive battery terminal first. The negative connection should then be made at the negative ground screw (or stud) on the engine. When the jumper cables are being removed, the negative connection (at the ground screw) is removed first and the positive connection (at the battery terminal) is removed last. Following this procedure will insure that any spark occurring when making or breaking the connection will be away from the hydrogen gas coming from the battery.
SAFETY WARNINGIt is quite likely that a spark will occur when the leads are connected or disconnected so extreme care must be taken that an explosive mixture is not present.
Anyone using a small "home charging unit" should be made aware of the potential hazard of shock or electrocution when using the charger around water. These dangers are greatly magnified if the unit is faulty or of poor construction.
Even a properly constructed charging unit can cause damage to the engine, alternator, or other electrical components on the boat if it is improperly connected. Probably the most obvious improper connection would be connecting the charger to the battery in reverse polarity. This would cause immediate alternator diode failure. A less obvious improper connection would be to have the charger connected to the battery through a high resistance. This high resistance connection could cause the charger to emit a transient high voltage resulting in damage to the boat or devices
on the boat itself. To protect against damage to the boat or engine electrical systems, the engine's positive battery cable should be disconnected at the battery before the charger is connected. The attaching points and sequence of connecting and disconnecting the charger's leads are the same as when connecting or disconnecting jumper cables.
SAFETY WARNINGWhen a battery is charging, it is creating a highly explosive gas. All charging should be done in a well ventilated area and only after making sure that the vents in the battery or battery caps are clear.
D. J. Leinonen
Technical Data Coordinator
DL/sn
NOTE: Post on all indexes under the heading "Electrical".