Johnson Service Bulletin SB-1335 - Eliminate the Warm-Up Choke
Issued February 1974, this bulletin describes disabling the warm-up choke on affected Johnson outboards to address excessive smoking, plug fouling, and rough running during cold-engine warm-up.
SB-#1335
February, 1974
SUBJECT: Eliminate the Warm-Up Choke
ON MODELS: All Models with Warm-Up Choke Feature
We have received some complaints of excessive smoking, plug fouling or rough running, due to excessive richness during the warm-up period. This is generally the first minute or so after starting a cold engine. We suggest that the warm-up choke be deactivated on motors with this condition.
To deactivate the warm-up choke, while insuring full choke operation with the toggle switch, make the exact changes by horsepower as follows:
1973 & 1974 Models -
50 H.P. - Disconnect the thermo-switch leads from terminals
#4 and #5 and tape. Install jumper, P/N 315004,
across terminals #5 and #6.
70 H.P. - Disconnect the thermo-switch leads from terminals
#6 and #8 and tape. Install jumper, P/N 315004,
across terminals #7 and #8.
V-4's - Disconnect the thermo-switch leads from terminals
#3 and #4 and tape. Move the remaining purple
wire with yellow stripe from terminal #4 to #1.
Install jumper, P/N 315004, across terminals #1
and #2.
1972 & Earlier - The exact procedure varies by model, year and
horsepower, but the general procedure is the same as above.
Disconnect the thermo-switch and wire the toggle switch so
that it energizes both coils of the choke solenoid.
Energizing both coils of the solenoid is necessary to insure solenoid operation when the battery is supplying current to crank a cold engine.
JOHNSON OUTBOARDS
D. J. Leinonen
D. J. Leinonen
Technical Data CoordinatorNOTE: Post on your 50 thru 135 H.P. index under heading "Electrical".