Johnson Service Bulletin SB-1359 (October 1974) - Cam - Point Timing

Factory guidance for adjusting ignition breaker points on 1974-1975 Johnson 9.9, 15 and 40 HP outboards, comparing the narrow 10° Fire Flash ignition cam setting area with the 46° area of earlier ignition cams.

Johnson Service Bulletin letterhead
SB-#1359

October, 1974

SUBJECT:   Cam - Point Timing

ON MODELS:   9.9, 15, and 40 H.P.

The point timing on the 1974 and 1975 9.9, 15 and 40 H.P. engines have a high point on the cam which is only 10° wide. On the P/N #318929 cam the set mark is cast on the top as shown in figure (1). The points must reach their widest point within the 10° of the set mark. The crankshaft of the 40 H.P. has the cam ground on it and there is no marking to show the 10° area where the points are fully opened. Use special care if you use a feeler gauge to set points on the 9.9, 15 or 40 H.P. engines with Fire Flash ignition.

Figure 1, 10 degree narrow point setting area on cam
Figure 1
Figure 2, 46 degree cam point setting area
Figure 2

Figure (2) shows the type of cam which is used on many of our engines that do not have Fire Flash ignition systems. The points remain open for approximately 46°, therefore, point adjustment is much easier on these engines. Keep this information in mind when servicing engines through 40 horsepower.

JOHNSON OUTBOARDS

D. J. Leinonen
Technical Data Coordinator

DJL/sn

NOTE: Post on your 2 through 40 H.P. engines under heading "Ignition".