Johnson Service Bulletin SB-1359 (October 1974) - Cam - Point Timing
Factory guidance for adjusting ignition breaker points on 1974-1975 Johnson 9.9, 15 and 40 HP outboards, comparing the narrow 10° Fire Flash ignition cam setting area with the 46° area of earlier ignition cams.

October, 1974
SUBJECT: Cam - Point Timing
ON MODELS: 9.9, 15, and 40 H.P.
The point timing on the 1974 and 1975 9.9, 15 and 40 H.P. engines have a high point on the cam which is only 10° wide. On the P/N #318929 cam the set mark is cast on the top as shown in figure (1). The points must reach their widest point within the 10° of the set mark. The crankshaft of the 40 H.P. has the cam ground on it and there is no marking to show the 10° area where the points are fully opened. Use special care if you use a feeler gauge to set points on the 9.9, 15 or 40 H.P. engines with Fire Flash ignition.


Figure (2) shows the type of cam which is used on many of our engines that do not have Fire Flash ignition systems. The points remain open for approximately 46°, therefore, point adjustment is much easier on these engines. Keep this information in mind when servicing engines through 40 horsepower.
D. J. Leinonen
Technical Data Coordinator
DJL/sn
NOTE: Post on your 2 through 40 H.P. engines under heading "Ignition".