Issued January 1975, this Johnson bulletin explains how faults in the alternator charging circuit can overheat stator charge coils on 85 through 135 H.P. Magneto C.D. ignition outboards.

Johnson Outboards Service Bulletin factory letterhead
SB-#1370

January, 1975

SUBJECT: Stator Service Tip

ON MODELS: 85 thru 135 H.P. with Magneto C.D. Ignition

When evidence of overheating of the charge coils is found during servicing of the stator (protective finish melted) be sure to test the complete alternator circuit before returning the engine to the customer. Charge coil failures of this type are caused by an open circuit in the charging system. When the alternator circuit opens, excessive current passes through the stator resulting in heat building up in the charge coils to the point of failure.

Refer to the appropriate service manual for detailed alter- nator circuit test procedures. A failed rectifier is usually caused by a loose or corroded electrical connection or a battery which has been improperly connected producing reverse polarity. Be sure the cause of the failure is found and corrected before returning the engine to service.

JOHNSON OUTBOARDS

D. J. Leinonen
Technical Data Coordinator
NOTE: Post on your 85 thru 135 H.P. indexes under heading
"Electrical".
DJL/kr

Tools, supplies and related parts

Suggested products related to this service bulletin. Verify fit and suitability before ordering.