Johnson Service Bulletin SB-1440 - Plastic Water Pump Impeller Housing Failures

July 1977 factory guidance on preventing water pump damage from running outboards without adequate cooling water.

Johnson Service Bulletin letterhead
SB #1440
July, 1977
SUBJECT: PLASTIC WATER PUMP IMPELLER HOUSING FAILURES
ON MODELS: ALL OUTBOARDS WITH PLASTIC WATER PUMP PROPELLER HOUSINGS.
We have had some reports of plastic water pump impeller housings failing prematurely, resulting in severe powerhead damage.
The cause of these premature failures has been traced to operation of the motor in test tanks, drive in test tanks and under other conditions where the gearcase is not deep enough in the water before starting. Other causes are starting the motor out of the water, such as before launching and before turning on the water when using flushing kits.
To prevent damaging the plastic water pump impeller housing, the water level at the gearcase must be at least to the spray deflector plate located above the anti-ventilation plate.
Motors with plastic impeller housings must never be run out of the water. The plastic housing can be damaged in as little as five to ten seconds.
If you have customers who use flushing devices when the motor is out of the water, we strongly recommend that you advise them that water must be turned on before starting motor.
JOHNSON OUTBOARDS

D. J. Leinonen
Technical Data Coordinator
DL/cld
NOTE: Post on 1 through V6 indexes under heading "Lower Unit".

Historical service reference

This bulletin cautions that plastic impeller housings may be damaged in five to ten seconds without cooling water. The factory advises establishing water flow before starting the motor, including when using flushing equipment.