SUBJECT: NECESSARY BREAK-IN RECOMMENDATIONS

MODELS: ALL 1979 V-6 MODELS

We have a few reports of 1979 V-6 motors experiencing piston seizure during the break-in period. Investigation has not revealed any mechanical reason for these early failures. Lack of proper attention to correct break-in procedure, along with fuel of questionable quality, appear to be significant factors.

Accordingly, we are asking you to emphasize to your customers, at time of delivery, the following items summarized from his owners’s manual:

  1. Use leaded regular fuel of at least 89 Pump Posted Octane (94 Research Octane).
  2. Use a BIA certified TCW lubricant at 50:1 ratio. Measure carefully and mix well.
  3. Avoid continuous full throttle operation for the 1st 10 hours. Brief intervals of full throttle operation (1-2 minutes) are beneficial during this period.

Also, we recommend that all V-6 outboards in your stock, which have not completed break-in, have the spark timing retarded 4°. This will reduce the heat load on the pistons during the critical break-in period. After completion of the break-in period, it is permissible, but not mandatory to advance the timing to the normal setting, which will result in an increase of less than 1 mph on most boats. Spark timing should be checked on both #1 & #2 cylinders, and if a difference is observed, set timing on the cylinder showing the most advance. Never exceed the spark timing specified.

Motors produced after approximately May 20th, will have the timing set 4° retarded at the factory and, will be tagged to indicate this.

Note: Post on V-6 index under heading “Miscellaneous.”
JOHNSON OUTBOARDS
D. J. Leinonen