Johnson Service Bulletin SB-1504 (August 1979) - Timer Base Leads Interference

Johnson's 1979 service instructions for preventing timer base leads from contacting the starter motor or flywheel on V4 outboards.

Johnson Service Bulletin factory letterhead
SB-1504
August 1979
SUBJECT: Timer Base Leads Interference - 1979 V-4 Models
It is possible for timer base leads to get caught by the starter motor or flywheel on 1979 V-4 motors.
The timer base leads should be clamped as shown in Figure 1. This will prevent the leads from being damaged by the starter motor pinion or the flywheel. Check the position of this clamp when servicing motors to prevent this occurrence.
Figure 1: starter motor and timer base lead clamp, 4 inches from end of timer base to clamp
Johnson Outboards

D. J. Leinonen
Technical Data Coordinator
Note: Post on V-4 Index under heading “Ignition”
CR 79-40