SB-1506 - Gearcase Lubricant Level
Issued in August 1979, this Johnson Service Bulletin reminds dealers to verify gearcase lubricant levels before delivering new outboards and summarizes recommended maintenance intervals.

SB-1506
August 1979
SUBJECT: GEARCASE LUBRICANT LEVEL - ALL MODELS
Our Warranty Department has reported that several gearcases have been returned with major component failures due to low lubricant level.
NOTE
INSUFFICIENT GEARCASE LUBRICANTS WILL CAUSE
SERIOUS DAMAGE TO LOWER UNIT COMPONENTS.
SERIOUS DAMAGE TO LOWER UNIT COMPONENTS.
We highly recommend that dealers check the gearcase lubricant level on all new motors, and “top off,” if necessary, before delivering to the customer. This should be done slowly as many gearcases require air to escape to allow gearcase lubricant to reach proper level.
All Owner’s/Operator’s Manuals state that the gearcase lubricant should be changed after the first 20 hours of operation and checked after 50 hours of operation. Add lubricant, if necessary. Drain and refill every 100 hours of operation or once each season, whichever occurs first.
Johnson Outboards
D. J. Leinonen
Technical Data Coordinator
D. J. Leinonen
Technical Data Coordinator
Note: Post on 2 thru V-6 models under heading “Lower Unit”
CR 79-42
© OUTBOARD MARINE CORPORATION 1979 ALL RIGHTS RESERVED
Factory references
This bulletin applies to all models and directs dealers to file it under “Lower Unit.”