SPB-481 - CD-77 Voltmeter CD Tester
Issued May 1977, this Johnson Service Promotion Bulletin introduces the Stevens Instrument Company CD-77 peak-reading voltmeter for testing capacitor-discharge ignition systems. The original two-page factory publication is reproduced below.

May, 1977
SPB-#481
SUBJECT: CD-77 Voltmeter CD Tester
Outboard Marine Corporation has developed a new Multiple Range Peak Reading Voltmeter which presents a new, more accurate, method in troubleshooting the capacitor discharge ignition systems on our engines.
This new Multiple Range Peak Reading Voltmeter is being manufactured and sold under a patent license agreement by:
Stevens Instrument Company
111 Greenwood Avenue
Waukegan, Illinois 60085
Telephone Number (312) 336-9375
Other non-licensed voltmeters may be available which may function satisfactorily in troubleshooting the capacitor discharge ignition systems on our engines.
Since the Multiple Range Peak Reading Voltmeter is not manufactured by nor is it a product of Outboard Marine Corporation, OMC is not responsible for and disclaims any liability for injury or damages arising out of the use or misuse of this voltmeter. In addition, any warranty coverage for the Multiple Range Peak Reading Voltmeter comes from the manufacturer, and accordingly, this product is not covered under warranty by OMC.

(OVER)
JOHNSON MOTORS, DIVISION OF OUTBOARD MARINE CORPORATION, WAUKEGAN, ILLINOIS 60085
MODEL CD-77 VOLTMETER FEATURES
Overall size measuring 4 1/4” wide, 5” high and 2 1/4” deep.
Readability is enhanced by utilizing the full width of the meter for the scales, a 100 degree sweep of the meter needle, and an extended radius which flattens the printed scales.
Separate scales are provided for each range . . . 0-5, 0-50 & 0-500. The 0-5 scale is printed in red.
The CD-77 is protected on all positions against accidental wrong hookups. Overload protection is automatic, with no need to replace fuses or reset a breaker. In addition, a warning light located in the center of the instrument panel glows during heavy overload conditions.
The bale type handle can be used for hanging the meter and is friction mounted to permit propping the instrument on a flat surface at any convenient angle.
The test prod on the negative lead plugs into the base of the ground clip, enabling this lead to be used either as a prod or as a clip. Both prods are the correct size for plugging into the connectors on the CD-2 systems.
Jumper leads are furnished to complete all necessary hookups.
D.J. Leinonen
Technical Data Coordinator
DJL/kr
NOTE: Post on your Service Promotion Index under heading “Test Equipment”.
Historical notes
The CD-77 was intended for peak-reading ignition tests. This bulletin also records the manufacturer's original contact information and OMC's warranty disclaimer.