OMC Bulletin No. 2049 explains how to test a potentially shorted operating switch lead on 1982 foot-controlled electric outboards.
Subject: Test for Shorted Operating Switch Lead
Models: 1982 Foot Control Electric Outboards
Some of the early 1982 12-volt and 12/24-Volt Foot Control Electric models may have a shorted on/off operating switch lead. One of the following may indicate a shorted switch:
- Extensive electrolysis corrosion of submerged parts is noticed.
- The motor begins to run when the battery leads are connected to a battery. In this case, another lead would also be shorted.
- Arcing occurs when the battery leads are being connected. This could occur if the motor is mounted on an aluminum boat and the switch lead is shorted.
A suspected switch can be tested with an ohmmeter and a condenser tester.
To test a suspected switch lead using an ohmmeter:
Note Disconnect the motor from the battery before connecting the ohmmeter to avoid damaging the ohmmeter.
- Remove the switch and bracket assembly from the foot pedal. Do not disconnect the switch leads.
- Select a high ohm scale on the ohmmeter.
- Connect the ohmmeter red lead (+) to the red battery lead (A). See illustration.
- Connect the ohmmeter black lead (-) to the switch bracket (B). See illustration.
- Move the 12/24-volt selector switch to the 24-volt position.
- Move the master switch and the operating switch to the “on” position.
(Continued)
- If the ohmmeter indicates continuity (short), repair the lead or replace the operating switch.
- If the ohmmeter shows no continuity (open), further testing should be done using a condenser tester.
To test the switch lead using a condenser tester:
- Connect the condenser tester leads the same as the ohmmeter leads. Disconnect the ohmmeter for this test.
- Move operating switch “on”.
- The switch must be replaced if the condenser shows continuity from the battery lead to the bracket.
- If no short is indicated by either test, check the remaining wiring for shorts.
To test the wiring before installing the switch and bracket:
- Connect the ohmmeter red lead (+) to the red battery lead (A). See illustration.
- Connect the ohmmeter black lead (-) to an unpainted surface on the foot pedal.
- If no short is indicated, disconnect the ohmmeter and connect the condenser tester to the same locations as the ohmmeter.
- If a short is indicated by either tester, check wiring carefully to locate and repair the cause.
Wiring installed in the boat can also cause electrical problems. If the problem cannot be found in the Electric Outboard wiring, it will be necessary to check all other wiring in the boat.