Subject: Improved Adjusting Needle Retainer P/N 315232 (Red)
Models: 1983 and Earlier Outboards Using Low Speed Needle Retainer P/N 315232 (White)
Symptom: Low speed adjusting needle rotates open or closed resulting in loss of correct mixture adjustment.
Cause: Retainer does not provide sufficient friction on needle.
Solution: Replace the adjusting needle retainer with new (red) retainer P/N 315232 using the following procedure:
• Remove air silencer or choke bracket (if equipped).
• Remove low speed needle.
1• Use a “hook” tool to remove the retainer from “key hole” slot of carburetor.
2• Use a large flat punch to bottom new retainer in cavity.
• Install low speed needle and adjust to recommended initial setting.
• Install air silencer or choke bracket (if equipped).
• Run motor in test tank or on boat. Refer to the current service manual for specific mixture adjustment procedure.