Problem -
When using the Jackman Model 741 to test motors equipped with a rectifier/regulator, the diode in the charging circuit of the Jackman 741 must be bypassed or the alternator will not charge.
Solution -
⚠ 1. Disconnect battery leads from the battery.
2. Remove the six screws (A) and plate (B) from the back of the tester.
3. Attach a jumper lead (C) from the diode terminal (D) to the lower terminal (E). Make sure the jumper clips are attached securely and do not interfere with other components.
4. Reinstall the plate and the six screws securely.
5. Reconnect the battery terminals making sure the terminals are tightened securely.
NoteIf the battery leads are not tightened securely to the battery terminals or to the Jackman 741 tester battery terminals, it will cause an open circuit between the motor rectifier/regulator charging system and the battery. This condition will cause damage to the rectifier/regulator.
NoteRemove the jumper lead when running motors that are not equipped with a rectifier/regulator charging system.
NoteDo not operate motors to exceed 25 amps charging rate or the ammeter on the tester may be damaged.