OMC Service Bulletin No. 2117: Trim Sending Units

OMC Service Bulletin No. 2117 (July 1984) addresses trim sending units. It applies to Johnson® and Evinrude® Outboards, OMC® Stern Drive, OMC Sea Drive®.

OMC Outboard Service Bulletin
Midsection

No. 2117
July, 1984

Subject: Trim Sending Units

Models: Johnson® and Evinrude® Outboards, OMC® Stern Drive, OMC Sea Drive®

Problem: Damaged or faulty trim sending unit

Symptom: Inoperative or inaccurate trim gauge reading

Cause: Connecting B+ voltage (12 volts) direct to the sending unit will cause damage. Two ways to damage a sending unit are:

  • improper wiring to the instruments
  • momentary voltage through a tool