OMC blocking diode location and measurement chart for outboards with the S.L.O.W. overheat warning system.

OMC Outboard Service Bulletin
Electrical System
No. 2243
July, 1991
Subject:
Blocking Diode Servicing
Models:
All with S.L.O.W.™ Overheat Warning System
Problem:

Locating the blocking diode

Solution:

The blocking diode is in the motor’s electrical cable, connected to the TAN or YELLOW/RED wires.

To find the blocking diode for servicing, measure according to the chart below, its footnotes, and the illustrations. Instructions for diode replacement are provided in the repair kit.

Blocking diode connector locations - red and three or four wire connectors
ModelYearType of ConnectorDistance From Edge of Connector Ⓐ
20-301989 and newerRed2” (50.8 mm)
40-501989 and newerRed2¾” (69.9 mm)
45WML1989 and newerRed4½” (114.3 mm)
40TTL1990 and newer4 wire4” (101.6 mm)
60TTL/70TTL†1989 thru 19913 or 4 wire3¼” (82.6 mm) & 4” (101.6 mm)
60/701989 and newerRed5” (127 mm)
85TTL1991 models only*
120/1401988 and newerRed19¾” (501.7 mm)
150/175 - 90°1989 and newerRed16” (406.4 mm)
150/175 - 60°1991 and newerRed5½” (139.7 mm)
200/2251988 and newerRed24½” (609.6 mm)
V81988 and newerRed29¼” (743 mm)

† These models have two diodes. From the connector, measure the TAN wires 3¼” (82.6 mm) - measure the YELLOW/RED wire 4” (101.6 mm).

* Measure 9¼” (235 mm) from the RING TERMINAL on the yellow/red wire at the starter solenoid.