OMC Service Bulletin No. 2325 - Accessory Battery Connection

OMC April 1998 accessory battery connection bulletin for V4 and V6 FFI outboards, including circuit breaker P/N 983320 and wiring precautions.

OMC Technical Service Outboard Bulletin
ROUTE TO:SERVICE MANAGERSERVICE WRITERTECHNICIAN 1TECHNICIAN 2TECHNICIAN 3FILE
Electrical System
No. 2325
April, 1998
Subject:
Accessory Battery Connection
Models:
V4, V6 FFI™
Problem:

Connecting an aftermarket battery isolator to the charging circuit could cause running problems and could damage the engine.

Solution:

Never connect an external, aftermarket battery isolator to an FFI outboard.

1 FFI outboards have an accessory battery charging terminal A, at the bottom of the power distribution panel. A battery isolator circuit, built into the engine’s charging system, supplies isolated power to this accessory terminal.

12 The accessory terminal A must be connected to a 50 amp fuse or circuit breaker B. Use 10 Ga. wire with 125° F (52° C) rated insulation. The fuse or circuit breaker must be connected to the accessory (No.2) battery positive terminal. Install the circuit breaker or fuse, such as OMC P/N 983320, as close to the battery as possible to protect the 10 Ga. wire from a short.

Use only the accessory terminal to charge an accessory (No.2) battery.

Note Do not disconnect or alter any wires, or add any other wires to an FFI outboard charging system.

Factory illustration 1 for bulletin 2325Factory illustration 2 for bulletin 2325
CR98-19

Tools, supplies and related parts

Suggested products related to this service bulletin. Verify fit and suitability before ordering.

Amazon: tools and supplies

Marine Dual Battery Switch, Battery Box

Search for these supplies on Amazon

eBay: OMC / Evinrude OEM part 983320

Search for original or compatible replacement part 983320

Click here to search on eBay

Affiliate disclosure: EverythingOutboards may earn a commission from qualifying purchases. As an Amazon Associate, we earn from qualifying purchases.