OMC Outboard Service Bulletin No. 2327, April 1998. Battery care and fuse checks for FFI outboards. Models: All FFI Outboards.
Drechnician2 — 0) Tecunicians
Ci service manacen =] service wrirern §—L] TECHNICIAN
Ore
ROUTE To:
Electrical System
No. 2327
April, 1998
Subject:
Battery Care
Models:
All FFI™ Outboards
When the key switch is turned OFF, a solid-state
Problem:
control circuit in the ECU keeps part of the ECU
powered up for ten minutes. This control circuit
draws a small amount of current at all times. If an
FFI outboard is not operated for 30 days, the start-
ing battery will be discharged to the point where
the outboard might not start.
cn} If the outboard will not be operated for more
Solution:
than 30 days, either turn off the boat's battery
switch, OR remove fuse from position 7 @ of the
power distribution panel. See OMC Ops ion and
Maintenance Manual — Starting Section, Stopping
Engine.
Make sure the battery installed meets the minimum
recommendations in the OMC Operation and Main-
tenance Manual - Maintenance Section, Specifica-
tions. Make sure it is in good condition and that the
electrical connections are clean and tight.
If an FFI outboard has a battery that is too
small, is at a low state-of-charge, or is in marginal
condition, the battery might still crank the engine,
but at a slower speed. At the lower RPM there
might not be enough alternator output to operate
the fuel injection system, so the engine will not
start.
[21 iryou remove the fuse, attach a note to the key
to remind the operator to install the fuse before
attempting to start the outboard.
‘See OMC Service Manual, and OMC Oper: yn and
Maintenance Manual for battery storage and win-
terization procedures.
CR98-22