Johnson Service Bulletin SB-831 - Charging Batteries

February 28, 1961. This supplement to SB-813 cautioned dealers against reversed battery and charger connections on alternator-equipped engines, which could damage the rectifiers, 60-amp generator fuse, and voltage regulator.

Johnson Motors Service Bulletin letterhead
February 28, 1961
Bulletin No. SB-831 Electrical System (Supplement to SB-813)
SUBJECT: Charging batteries while connected to junction boxes of alternator equipped engines.
Paragraph 3.b. contained in Service Bulletin No. SB-813 has already cautioned you about being careful with battery polarity (battery cable connections) when working with alternator equipped engines. Briefly, if the battery is connected to the junction box with reversed polarity (battery cable connections reversed), the rectifiers will conduct full battery current and may be damaged before the 60-amp. generator fuse burns out. If the ignition switch is "ON" while polarity is reversed, the voltage regulator will also be damaged.
A similar danger exists when recharging batteries while they are connected to the junction boxes of alternator equipped engines. Since accidentally connecting the charger to the battery with reversed polarity is very easily done, the safest possible procedure to protect the 60-amp. fuse, and possibly the rectifiers, should the fuse fail to opportunely "blow", is to disconnect the battery from the junction box BEFORE connecting the charger. Disconnection is most conveniently accomplished by disconnecting the cables from the battery terminals.
The alternator system is rugged and efficient, has few moving parts subject to wear and is capable of charging at low engine speeds. For this reason, under normal operation and with all components of the generating circuit functioning as intended, recharging batteries should be an infrequent necessity. However, batteries may nevertheless require recharging as the result of customer forgetfulness in turning off ignition switches, accessories or lights. We therefore urge you to advise your customers, particularly the do-it-yourself variety, about exercising reasonable care in connecting battery and charger cables.
Keep in mind that blown 60-amp. generator fuses or damage to voltage regulators and rectifiers caused by reversed battery or charger cable connections is not damage which is attributable to faulty material, parts or factory workmanship.
JOHNSON MOTORS
W. W. DeWees Service Department
WWD:eb
NOTE: Post on your V-75 index.
W. W. DeWees handwritten signature

Related bulletin

SB-813 - Electrical System, the original bulletin supplemented by SB-831.