ELECTRICAL #1007
April, 1973
USE OF JUMPER CABLES & BATTERY CHARGING UNITS
ON ALL OUTBOARDS AND STERN DRIVES WITH ELECTRIC START
ON ALL OUTBOARDS AND STERN DRIVES WITH ELECTRIC START
We've received several inquiries regarding the advisability of using jumper
cables or small "home charging units" on outboard engines and stern drives.
cables or small "home charging units" on outboard engines and stern drives.
It is safe to connect jumper cables between boats to start a disabled engine, but
only if it is done in a proper manner. We recommend that the positive connection
be securely made at the positive battery terminal first. The negative connection
should then be made at the negative ground screw (or stud) on the engine. When
the jumper cables are being removed, the negative connection (at the ground screw)
is removed first and the positive connection (at the battery terminal) is removed
last. Following this procedure will insure that any spark occurring when making
or breaking the connection will be away from the hydrogen gas coming from the
battery.
only if it is done in a proper manner. We recommend that the positive connection
be securely made at the positive battery terminal first. The negative connection
should then be made at the negative ground screw (or stud) on the engine. When
the jumper cables are being removed, the negative connection (at the ground screw)
is removed first and the positive connection (at the battery terminal) is removed
last. Following this procedure will insure that any spark occurring when making
or breaking the connection will be away from the hydrogen gas coming from the
battery.
SAFETY WARNINGIt is quite likely that a spark will occur when the leads are
connected or disconnected so extreme care must be taken
that an explosive mixture is not present.
connected or disconnected so extreme care must be taken
that an explosive mixture is not present.
Anyone using a small "home charging unit" should be made aware of the potential
hazard of shock or electrocution when using the charger around water. These
dangers are greatly magnified if the unit is faulty or of poor construction.
hazard of shock or electrocution when using the charger around water. These
dangers are greatly magnified if the unit is faulty or of poor construction.
Even a properly constructed charging unit can cause damage to the engine, alternator,
or other electrical components on the boat if it is improperly connected. Probably
the most obvious improper connection would be connecting the charger to the battery
in reverse polarity. This would cause immediate alternator diode failure. A less
obvious improper connection would be to have the charger connected to the battery
through a high resistance. This high resistance connection could cause the charger
to emit a transient high voltage resulting in damage to semiconductor devices on
the boat itself. To protect against damage to the boat or engine electrical systems,
the engine's positive battery cable should be disconnected at the battery before the
charger is connected. The attaching points and sequence of connecting and discon-
necting the charger's leads are the same as when connecting or disconnecting jumper
cables.
or other electrical components on the boat if it is improperly connected. Probably
the most obvious improper connection would be connecting the charger to the battery
in reverse polarity. This would cause immediate alternator diode failure. A less
obvious improper connection would be to have the charger connected to the battery
through a high resistance. This high resistance connection could cause the charger
to emit a transient high voltage resulting in damage to semiconductor devices on
the boat itself. To protect against damage to the boat or engine electrical systems,
the engine's positive battery cable should be disconnected at the battery before the
charger is connected. The attaching points and sequence of connecting and discon-
necting the charger's leads are the same as when connecting or disconnecting jumper
cables.
SAFETY WARNINGWhen a battery is charging, it is creating a highly explosive
gas. All charging should be done in a well ventilated area and
only after making sure that the vents in the battery or battery
caps are clear.
gas. All charging should be done in a well ventilated area and
only after making sure that the vents in the battery or battery
caps are clear.
EVINRUDE MOTORS
Service Department
Service Department
NOTE: This bulletin replaces Electrical #1001