Evinrude Controls Bulletin #1014 - Remote Control Electrical Troubleshooting

June 1973 factory troubleshooting procedure for key-switch shutdown and remote-control grounding faults on 50-135 H.P. magneto CD ignition outboards, including a wiring schematic and battery-disconnection precaution.

1973 Evinrude Service Bulletin original factory letterhead
REMOTE CONTROL - ELECTRICAL TROUBLE SHOOTING
ALL MAGNETO CD IGNITION MODELS
50 - 135 H.P.
If the key switch or the control box ground circuit are defective, the result may
be one of two things:
1.   You may not be able to turn off the engine with the key switch.
2.   You may get a shock when touching the control box.
If either of these symptoms are reported, check the unit as follows:
NOTE: Disconnect battery before starting tests.
1.   Remove throttle & shift control cables from engine to eliminate
     possibility of reading a false ground.
2.   Using an ohmmeter set to the low ohms scale, check for good
     ground between ground terminals of engine and control box. If
     ohmmeter shows a high or infinite reading, the cause of excess
     resistance must be determined & corrected.
3.   Check the ignition switch and wiring to determine if they are
     defective. This can be done by first removing the black/yellow
     stripe lead from power pack ignition switch terminal (terminal
     5 on 50 h.p., 6 on 65 h.p., or 1 on 85-135 h.p.) and then con-
     necting ohmmeter between engine ground terminal and loose
     end of black/yellow stripe lead. With ignition switch in "off"
     position, meter should show low resistance. If reading is high
     or infinite, the wiring or switch are defective and must be
     repaired or replaced.
NOTE: Any electrical connections bared during tests should be recoated with
         liquid neoprene (Part No. 315417).
Factory schematic showing engine ground, black and black-yellow stripe ignition wires, and remote-control key switch
EVINRUDE MOTORS
Service Department