Back to 1970-1980 OMC service bulletins

Evinrude Fuel System Bulletin #1038 - Warm-Up Choke, 50-135 HP

February 1974 factory instructions for disabling the automatic warm-up choke on Evinrude 50 HP, 70 HP and V-4 outboards when excessive richness causes smoking, plug fouling or rough running. Includes the terminal changes and jumper P/N 315004.

Evinrude Service Bulletin factory header
FUEL SYSTEM #1038
February, 1974
WARM-UP CHOKE 50-135 HP MODELS

We have received some complaints of excessive smoking, plug fouling or rough running, due to excessive richness during the warm-up period. This is generally the first minute or so after starting a cold engine. We suggest that the warm-up choke be inactivated on motors with this problem.

To inactivate the warm-up choke, while insuring full choke operation with the toggle switch, a jumper #315004 and in some cases moving a wire on the terminal strip is required in addition to disconnecting the choke thermo-switch. The exact changes vary by horsepower as follows:

1973 & 1974 Models -
50 HP -
Disconnect the thermo-switch leads from terminals #4 and #5 and tape. Install jumper across terminals #5 and #6.
70 HP -
Disconnect the thermo-switch leads from terminals #6 and #8 and tape. Install jumper across terminals #7 and #8.
V-4's -
Disconnect the thermo-switch leads from terminals #3 and #4 and tape. Move the remaining purple/yellow wire from terminal #4 to #1. Install jumper across terminals #1 and #2.

1972 & Earlier - The exact procedure varies by model year and horsepower, but the general procedure is the same as above. Disconnect the thermo-switch and wire the toggle switch so that it energizes both coils of the choke solenoid.

Energizing both coils of the solenoid is necessary to insure solenoid operation when the battery is supplying current to crank a cold engine.

EVINRUDE MOTORS
Service Department