← Back to 1970s OMC service bulletins

Evinrude Service Bulletin #1160 - Plastic Water Pump Impeller Housing Failures

July 1977 Evinrude lower-unit service bulletin warning about premature plastic water-pump impeller housing failures caused by insufficient water supply, including operation in test tanks and with flushing devices.

Evinrude Service Bulletin factory letterhead
LOWER UNIT #1160
July, 1977
SUBJECT:   PLASTIC WATER PUMP IMPELLER HOUSING FAILURES

We have had some reports of plastic water pump impeller housings failing prematurely, resulting in severe powerhead damage.

The cause of these premature failures has been traced to operation of the motor in test tanks, drive in test tanks and under other conditions where the gearcase is not deep enough in the water before starting. Other causes are starting the motor out of the water, such as before launching and before turning on the water when using flushing kits.

To prevent damaging the plastic water pump impeller housing, the water level at the gearcase must be at least to the spray deflector plate located above the anti-ventilation plate.

Motors with plastic impeller housings must never be run out of the water. The plastic housing can be damaged in as little as five to ten seconds.

If you have customers who use flushing devices when the motor is out of the water, we strongly recommend that you advise them that the water must be turned on before starting motor.

EVINRUDE MOTORS
Service Department