STARTER #1209
December, 1978
SUBJECT: V-6 STARTER MOUNTING BOSS
MODEL: ALL V-6'S
It has been brought to our attention that the upper rear starter mounting boss on some V-6 outboards may break in severe service.
Breakage of this boss may occur where the bottom starter mounting bolt is loose and the full starting load is placed on the top bosses.
When encountering a broken boss as shown in Figure 1, a salvage procedure to provide threads in solid section would be as follows:

1. Remove the starter motor and apply DeVcon® 5 minute epoxy or equivalent 5 minute epoxy. This can be purchased at your local hardware stores. This kit is shown in Figure 2.
2. Follow the instructions on the DeVcon carton and mix thoroughly as shown in Figure 3.

3. Apply DeVcon to both broken surfaces, press the broken boss on the casting as shown in Figure 4.

4. Bolt the starter motor on the engine with the top front bolt and the bottom bolt.
5. Use a letter F drill, wrapping tape 2-3/8" from the end of the drill. Use the tape as your guide to drill the hole 2-3/8" deep. Use hole in the starter bracket as a guide to drill the hole straight as shown in Figure 5.

6. Next use an 11/32" drill. Tape the drill to the depth of the fracture as shown in Figure 6.

7. Drill the hole as shown in Figure 7.

8. Using a 5/16-18 starting tap, tap to the bottom of the hole. Clean the chips out of the hole. Use a bottom tap to assure threads are to the full depth of the hole as shown in Figure 8.

9. Install a 2" long bolt (P/N 306424) and torque all bolts to 10-12 ft. lbs. or 14.0-16.0 N.m.

EVINRUDE MOTORS
Service Department