SB-1327 - Sensors Grounding to Sensor Shield

Issued October 1973, this Johnson Service Bulletin explains how to detect ignition sensor leakage to the shield on 50 through 135 H.P. outboards with the Mag Flash system. The factory instructions and tester photograph are reproduced below.

Johnson Outboards Service Bulletin factory letterhead
SB-#1327
October, 1973
SUBJECT: Sensors Grounding to Sensor Shield
ON MODELS: 50 thru 135 H.P. with "Mag Flash" System
In some conditions, sensors may be grounding out to the shield
but will not show up with an ohmmeter. This condition may be
found by using the condenser tester leakage test, where a
voltage of approximately 500 volts is applied to the sensor.
See diagram below:
Factory photograph of condenser leakage tester connected to the ignition sensor assembly
(Disconnect all sensor leads from power pack)
Ground the black lead of the tester to the timer base assembly.
Attach the red lead of the tester to one of the sensor leads and
apply the leakage test. Repeat test on each sensor lead. Meter
will indicate if shorting.

JOHNSON OUTBOARDS

D. J. Leinonen

Technical Data Coordinator

DL/sn
NOTE: Post on your 50 thru 135 H.P. indexes under the heading
"Ignition".